NTI PRIMUX MATRIX KVM SWITCH VIA CAT 5
Distances and Resolutions for CAT5/CAT5e and CAT6 Cables (Continued)
CABLE
DISTANCE (feet)
CAT6 (UTP)
CAT6 (UTP)
CAT6 (UTP)
CAT6 (UTP)
CAT6 (UTP)
CAT6 (UTP)
INTERCONNECTION CABLE WIRING METHOD
The connection cable between the Matrix Switch and Host Adapter is terminated with RJ45 connectors and must be wired
according to the EIA/TIA 568 B industry standard. (This is also the pinout of a patch cable used to connect the Matrix Switch to a
LAN.) Wiring is as per the table and drawing below.
Pin
Wire Color
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
SH
Drain wire
PC-TO-MATRIX SWITCH CROSSOVER CABLE
In order to make a direct connection between a PC and the ETHERNET connector of the PRIMUX Matrix Switch, a crossover
cable must be used. The cable is made with CAT5 cable terminated with RJ45 connectors and wired according to the chart
below.
Pin assignment at
Standard End
1
2
3
4
5
6
7
8
Shield
RESOLUTION
1000
1024x768 at 60Hz
800
1024x768 at 60Hz
600
1280x1024 at 60Hz
500
1280x1024 at 60Hz
300
1600x1200 at 60Hz
100
1920x1440 at 60Hz
Pair
Function
2
T
2
R
3
T
1
R
1
T
3
R
4
T
4
R
-
Shield
Wire Color
Pin assignment at
Crossed End
White/Orange
3
Orange
6
White/Green
1
Blue
4
White/Blue
5
Green
2
White/Brown
7
Brown
8
Drain wire
Shield
Figure 64- View looking into RJ45 female
Standard
End
60
Pair 3
Pair 2
Pair 1
Pair 4
T
R
T
R
T
R
T
R
1
2
3
4
5
6
7
8
+
-
+
-
+
-
+
-
Crossed
End
Crossover Cable