NTI PRIMUX MATRIX KVM SWITCH VIA CAT 5

System Configuration Menu

Press <A> -<S> from the Command Mode menu to display the System Configuration menu.
Function
Description
Logoff Timeout
Open an edit field to set the time in minutes after which a user will
be logged out of Command Mode due to inactivity.
Range= 0-255 minutes (value of 0 disables the feature)
Alternate OSD Key
Define an alternative key to use with <Ctrl> to enter Command
Mode
OSD Blank Timeout
Set the time in minutes for the OSD screen to blank out due to
inactivity- moving the mouse or pressing a key on the keyboard will
redisplay the OSD
Range= 0-255 minutes (value of 0 disables the feature)
Configure DDC
Opens a Host Adapters list in which DDC can be sent from the
monitor to specific host adapters
Delete All Hosts
Deletes all Host Adapters listed- requires confirmation
Delete All Users
Deletes all configured Users- requires confirmation
Sharing Timeout
*shown only in Matrix Mode*(page 36)- when a host is in full share
mode (page 31) , this is the time after which a user will relinquish
control so that another user may take control.
Range= 2-255 seconds
Help
Display topic specific help page

Figure 28- System Configuration menu

29
Keystroke
L – (000-
255)
A
I
D
H
U
F1