Scan Mode; Normal Mode - Network Technologies PRIMUX-16X64 Installation And Operation Manual

Kvm matrix switch via catx
Hide thumbs Also See for PRIMUX-16X64:
Table of Contents

Advertisement

NTI PRIMUX MATRIX KVM SWITCH VIA CAT 5
Function
Display first 8 Host Adapters and move selection bar to the first
Display last 8 Host Adapters and move selection bar to the last
Press to toggle enable/disable Scan Mode
Enter Settings Menu
Enter Administration Mode
(Administrator only- see page 28)
Find- select Host Adapter by name
Display Command Mode Help Menu
Connect to the highlighted Host Adapter
Toggle between listing all accessible Host Adapters and listing only
accessible "Favorite" Host Adapters
Disconnect from the currently connected Host Adapter- no CPU
connection will be displayed behind the OSD menu
Log Out the User/Administrator and disconnect from the Host Adapter
The login screen will appear (page 20)
Exit Command Mode without logging out
The mouse can also be used to control the User Station Command Mode.
• The scroll wheel can be used to scroll through the Host Adapters list.
• The mouse cursor can be moved to the any of the command fields where the user can click on
the left mouse button to select that function.
• Host Adapters listed on the screen can be selected by moving the cursor onto a Host Adapter.
• To connect to a Host Adapter, click on the selected Host Adapter.
• To move through the Host Adapter list, the scroll bar to the right of the list can be used by clicking the up and
down arrows.
Note: Exit Command Mode to enter Normal Mode and control the connected CPU. To exit Command Mode, press <Esc>.

Scan Mode

To activate Scan Mode press <S> from the Command Mode menu.
Scan Mode enables the user to scan through selected Host Adapters (unless they are powered-OFF) and to have full device
control of the connected powered-ON Host Adapter. From the Settings menu (page 23) the user can edit the list of Host Adapters
that can be scanned. A Host Adapter is skipped from the scan cycle if the Host Adapter is not selected in the scan list (page 25).
When switching to a new Host Adapter the Host Adapter name is displayed by OSD for 4 seconds. When the user moves the
mouse or types on the keyboard the scanned Host Adapter becomes active and scanning is stopped. The switch will resume
scanning after a period of user inactivity determined by the scan dwell time. The scan dwell time is programmable from 2 to 255
seconds (default time-out period is 5 seconds). See Settings Menu (page 23) for configuring the scan dwell time.
Note: The keyboard and mouse must remain idle for the full scan dwell time before the switch selects the next active
Host Adapter.

Normal Mode

When the User Station is not in Command or Scan mode and the OSD control menu is not active on the monitor, the user is in
Normal Mode, controlling the CPU to which the user is connected through the PRIMUX switch.
Keystroke
Home
End
S
T
A
F
F1
Enter
V
D
L
Esc
22