INTERCONNECTION CABLE WIRING METHOD

The cable connecting the terminals and devices to the SERIMUX must be terminated with RJ45 connectors and must be wired
according to the EIA/TIA 568 B industry standard. Wiring is as per the table and drawing below.
Pin
Wire Color
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown

TROUBLESHOOTING

If the Console Switch is not working properly, consider the suggestions below to see if a solution can be found.
Problem
No Front Panel LEDs are illuminated
SERIMUX is not working properly
Cannot Connect to port/device
Commands entered from front panel
keypad are not accepted
SERIMUX will not accept username
or password
Cannot access user menu on a port
I cannot access the View Port Data
Buffer
If the passwords or other important parameters are not available, the SERIMUX Console Switch can be re-initialized to the default
settings (see "Initialize SERIMUX Console Switch to default settings" on page 34).
Caution: During initialization, the customer modified parameter values will be replaced with the factory
default values; all ports will be placed in buffer mode; all passwords will be erased.
If the suggestions above have been tried and the NTI Console Switch is still not functioning properly, a solution to the problem
may be found on our website at http://www.networktechinc.com in our FAQ (Frequently Asked Questions) section, or, please call
us directly at (800) 742-8324 (800-RGB-TECH) in the US & Canada or (330) 562-7070 (Worldwide) and we'll be happy to assist
in any way we can.
Pair
Function
2
T
2
R
3
T
1
R
1
T
3
R
4
T
4
R
Cause
No power to SERIMUX
Poor Connections
Port not configured correctly
Ports not initialized
Port settings not correct
Wrong cable adapter used
Connections are loose
Buttons are being pressed too rapidly
Usernames and passwords are case
sensitive
Port is configured as host port
Only the ROOT user can access this (see
page 14)
55
Pair 3
Pair 2
Pair 1
Pair 4
T
T
R
R
T
R
T
1
2
3
4
5
6
7
+
-
+
-
+
+
-

Figure 61- View looking into RJ45 female

Solution
Check all power connections
Verify that all cables are securely
connected
Verify that the port configuration
matches that of the device connected
Power-up the CPUs first, then the
SERIMUX
Verify proper communication settings
(pg 8)
Verify that adapter is one specified in
Appendix C.
Verify that all cable connections are
secure
1)
Make sure the Keypad PIN is
entered properly.
2)
Press the "Enter" key before typing
the PIN to discard the previous
entry.
3)
Try the PIN again but slow down
the button sequence- approx 1/2
sec between each press.
Verify characters used and enter again.
Configure port as user port. (pg. 10)
Login as the ROOT user
R
8
-