Rs232 Command Protocol; Rs232 Command Protocol Quick Reference - Network Technologies PRIMUX-16X64 Installation And Operation Manual

Kvm matrix switch via catx
Hide thumbs Also See for PRIMUX-16X64:
Table of Contents

Advertisement

NTI PRIMUX MATRIX KVM SWITCH VIA CAT 5

RS232 Command Protocol

Host controller commands supported by the unit are defined below.

RS232 Command Protocol Quick Reference

Legend:
(All numbers must be two digits)
BR :
Baud Rate Code (12,24,48,96,19,38,57,11)
OP :
Output/User Port (01-MAXOUTPUTS)
IP
:
Input Port/CPU (01-MAXINPUTS)
<CR>:
Carriage Return (Hex 0xD)
Command String
Good Response
CF 01
CS 01,OP,IP
*<CR>
CA 01,IP
*<CR>
RO 01,OP
*<CR>IP<CR>
CB 01,BR
None
RV 01,00
*<CR>string\0<CR>
RU 01
*<CR>IP,OP<CR>
GO 01 OP
*<CR>go 01 OP IP<CR>
GM 01,00
*<CR>go 01 OP IP<CR>
(all connections)
EA 01,ip
*<CR>
RA 01
*<CR>ip<CR>
EG 01,ip
*<CR>
RG 01
*<CR>ip<CR>
EM 01,ip
*<CR>
RM 01
*<CR>ip<CR>
If the first field is not a known command (as listed above) the command will be ignored. If the syntax is wrong after the first two
fields (first 4 characters), the switch will answer with ?<CR>.
Syntax example:
(insert the space and commas as shown)
CS 01,02,05<CR>
which means "At the switch with unit address 01, connect user port 02 to CPU port 05"
The switch will answer with:
∗<CR>
The HEX code representation of example above is:
Byte 1 Byte 2
Byte 3
'C'
'S'
Space
(0x43)
(0x53)
(0x20)
Byte 10
Byte 11
Input –1st digit
Input –2nd digit
(0x30)
(0x32)
Response:
Byte 1
Byte 2
<CR>
'∗'
(0x0D)
(0x2A)
Description
Switch to Configuration Menu.
Connect one User port To CPU (Host Adapter) port
Connect all User ports To CPU (Host Adapter) port
Read Connection For User Port
Change Baud Rate For All Switches (BR=12 (1200), 24 (2400), 48
(4800), 96 (9600), 19 (19200), 38 (38400), 57 (57600), 11 (115000)
baud) (9600 is the default)
Read NTI Version String
Read Unit Size
Report the User port that is connected to the CPU port
List all switch User port connections; all User ports to all CPU ports
Set the IP address, ip is in xxx.xxx.xxx.xxx format (number of digits is
minimum 1 and maximum 3, leading zeros accepted)
Read the IP address
Set the default gateway, ip is in xxx.xxx.xxx.xxx format (number of
digits is minimum 1 and maximum 3, leading zeros accepted)
Read the default gateway
Set the IP mask, ip is in xxx.xxx.xxx.xxx format (number of digits is
minimum 1 and maximum 3, leading zeros accepted)
Read the IP mask
Byte 4
Byte 5
Switch – 1st digit
Switch – 2nd digit
(0x30)
(0x31)
Byte 12
<CR>
(0x0D)
Byte 6
Byte 7
','
Output – 1st digit
(0x2C)
(0x30)
42
Byte 8
Byte 9
Output – 2nd digit
','
(0x35)
(0x2C)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primux-8x32

Table of Contents