Section 4: Adjust the Image
4.10 Fold Mirror Adjustment
If a corner or edge of an image is missing, the fold mirror might be misaligned with the optical system. To
correct this issue:
• Adjust the screw closest to the operator's side (right side, when facing screen) to raise or lower the image.
• Adjust the screw on the left side to move the image left or right.
4-6
Figure 4-9 Fold Mirror Adjustment
CP4230 Setup Guide