Standard 2 of 5 Length Mode Settings and Descriptions
Setting
Mode
Length 1
Length 2
Length 3

Sweden Post Settings

This section lists all configurable settings for decoding the Sweden
Post symbology.
Sweden Post Settings and Descriptions
Setting
User defined symbology ID
Code mark
Description
Sets the length mode for Standard 2 of 5 decoding.
Options include:
Length 1 minimum (default)
Lengths 1,2,3 fixed
Length 1 minimum, length 2 maximum
Restricts the length of the bar code that the scanner
will read. Range is 0 to 255. Default is 6.
Restricts the length of the bar code that the scanner
will read. Range is 0 to 255. Default is 0.
Restricts the length of the bar code that the scanner
will read. Range is 0 to 255. Default is 0.
Description
Sets the symbology ID for Sweden Post.
Range is 1 to 4 ASCII characters. \xFF is
not supported.
Default is P7.
A one-character code mark that serves as
an identifier for Sweden Post.
Default is *.