CHAPTER 4 PCI Card Hot Maintenance in Red Hat Enterprise Linux 6
4.6 Hot Replacement of PCI Express Cards
# /sbin/iscsiadm -m session
tcp: [1] 192.168.1.64:3260,1 iqn.2000-
09.com.fujitsu:storage-system.eternus-
dx400:00001049.cm0ca0p0
d. You can confirm the disconnection of sessions on multipath products using DM-MP or ETERNUS
multidriver.
*1: Write down the DM-MP display contents at the session disconnection.
Example of DM-MP display before disconnecting path
# /sbin/multipath -ll
mpath1 (36000b5d0006a0000006a104900000000) dm-0
FUJITSU,ETERNUS_DX400
[size=50G][features=0][hwhandler=0][rw]
¥_ round-robin 0 [prio=2][active]
¥_ 3:0:0:0 sdb 8:16
¥_ 4:0:0:0 sdc 8:32
Example of DM-MP display after disconnecting path
# /sbin/multipath -ll
mpath1 (36000b5d0006a0000006a104900000000) dm-0
FUJITSU,ETERNUS_DX400
[size=50G][features=0][hwhandler=0][rw]
¥_ round-robin 0 [prio=1][enabled]
¥_ 3:0:0:0 sdb 8:16
*2: See the ETERNUS Multipath Driver User's Guide (For Linux).
Work to be performed after NIC replacement
For iSCSI (NIC) hot replacement, be sure to follow the procedure below when Step 19 of the
replacement procedure
1. To restore access to the iSCSI connection interface, perform the following.
a. Confirm the state of multiple path by DM-MP (*1) or EMPD (*2).
b. Use the iscsiadm command to log in to the path (iqn) through which the replacement iSCSI card is
routed, and reconnect the session.
Example which confirms the state of session before connecting:
# /sbin/iscsiadm -m session
tcp: [1] 192.168.1.64:3260,1 iqn.2000-
09.com.fujitsu:storage-system.eternus-
dx400:00001049.cm0ca0p0
Example which login path going through a NIC to be replaced:
# /sbin/iscsiadm -m node -T iqn.2000-09.com.fujitsu:storage-
system.eternus-dx400:00001049.cm1ca0p0 -p 192.168.2.66:3260
–login
c. Use the iscsiadm command to confirm that the target session has been activated.
Example which confirms the state of session after connecting
# /sbin/iscsiadm -m session
tcp: [1] 192.168.1.64:3260,1 iqn.2000-
09.com.fujitsu:storage-system.eternus-
dx400:00001049.cm0ca0p0
tcp: [3] 192.168.2.66:3260,3 iqn.2000-
09.com.fujitsu:storage-system.eternus-
dx400:00001049.cm1ca0p0
d. You can confirm the activation of sessions on multipath products using DM-MP or ETERNUS
multidriver.
*1: Write down the DM-MP display contents at the session activation.
Example of DM-MP display before connecting path
# /sbin/multipath -ll
mpath1 (36000b5d0006a0000006a104900000000) dm-0
FUJITSU,ETERNUS_DX400
[size=50G][features=0][hwhandler=0][rw]
[active][ready]
[active][ready]
[active][ready]
in
4.6.4 Network card replacement
103
procedure.
NIC
C122-E175-02EN