CHAPTER 7 PCI Express card Hot Maintenance in Windows
7.5 Hot Replacement Procedure for iSCSI
7.5.2 Disconnecting MPD
This section describes the procedure for disconnecting MPD.
1. Start ETERNUS Multipath Manager.
2. Confirm the address value recorded in step 10 in
Then, place the target device offline. For a multifunction card, it is necessary to place more than one
device offline.
Note
In case of multi-function card, there are some cards that have same segment number, same bus number,
and different function numbers.
In this case, please perform step.3 to step.5 of follows respectively.
3. Confirm target NIC in Device Manager.
Confirm NIC with step 2-a at
PCI Express
4. Disable target NIC in Device manager.
Disable NIC with step 2-b at
PCI Express
5. Stop target NIC by using safely remove devices from computer.
Stop NIC with step 3 at
Express
cards.
7.2.1 Replacement procedure
cards.
7.2.1 Replacement procedure
cards.
7.2.1 Replacement procedure
7.5.1 Confirming the incorporation of a card with
in
7.2 Common Hot Plugging Procedure for
in
7.2 Common Hot Plugging Procedure for
in
7.2 Common Hot Plugging Procedure for PCI
189
MPD.
C122-E175-02EN