Configuring Ufd; Example Of Ufd Configuration - HP ProCurve 6120G/XG Configuration Manual

Procurve series 6120 blade switches management and configuration guide
Hide thumbs Also See for ProCurve 6120G/XG:
Table of Contents

Advertisement

Port Status and Configuration
Uplink Failure Detection

Configuring UFD

You must first enable UFD by entering this command in global context.
Syntax: [no] uplink-failure-detection
Then configure the LtM to LtD pairings. There are nine uplinks, so up to nine
track IDs can be configured.
Syntax: [no] uplink-failure-detection track <1-64> links to monitor <monitor-list>

Example of UFD Configuration

ProCurve(config)# uplink-failure-detection
Procurve(config)# uplink-failure-detection track 1 links-to-monitor Trk5
links-to disable 3,12
ProCurve(config)# uplink-failure-detection track 2 links-to-monitor 23-24
links-to-disable 9
ProCurve(config)# uplink-failure-detection track 5 links-to-monitor 17 links-
to-disable 7,14
Figure 10-25. Example of Configuring Uplink Failure Detection
10-40
Globally enables Uplink Failure Detection on the switch.
The no form of the command disables Uplink Failure Detection.
Default: Disabled
links to disable <disable-list>
Globally enables Uplink Failure Detection on the switch.
The no form of the command disables Uplink Failure Detection.
Default: Disabled

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 6120xgProcurve 6120 series

Table of Contents