==========================- CONSOLE - MANAGER MODE -==========================
System Name : ProCurve
System Contact :
System Location :
Inactivity Timeout (min) [0] : 0
Inbound Telnet Enabled [Yes] : Yes
Time Sync Method [None] : TIMEP
TimeP Mode [Disabled] : Disabled
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Actions->
Cancel
Figure 9-20. The System Information Screen (Default Values)
Press [E] (for Edit). The cursor moves to the System Name field.
2. Use [v] to move the cursor to the Time Sync Method field.
3. If TIMEP is not already selected, use the Space bar to select
4. Do one of the following:
Switch Configuration - System Information
Edit
Save
press [v] once to display and move to the TimeP Mode field.
Use the Space bar to select the DHCP mode, then press
•
the cursor to the Poll Interval field, and go to step 6.
Use the Space bar to select the Manual mode.
•
[>]
to move the cursor to the Server Address field.
i. Press
ii. Enter the IP address of the TimeP server you want the switch to
use for time synchronization.
Note: This step replaces any previously configured TimeP server
IP address.
[>]
to move the cursor to the Poll Interval field, then go to
iii. Press
step 6.
TimeP: Viewing, Selecting, and Configuring
MAC Age Time (sec) [300] : 300
Web Agent Enabled [Yes] : Yes
Time Protocol Selection Parameter
– TIMEP (the default)
– SNTP
– None
Help
Time Protocols
TIMEP
, then
[v]
to move
9-29