The show sflow <instance> sampling-polling [port-list] command displays infor­
mation about sFlow sampling and polling on the switch. You can specify a list
or range of ports for which to view sampling information.
ProCurve# show sflow 2 sampling-polling 1-4
Port
| Sampling
| Enabled
----- + -------- -------- ------
1
Yes(2)
2
---
3
No(1)
4
Yes(3)
Figure 13-15. Example of Viewing sFlow Sampling and Polling Information
N o t e
The sampling and polling instances (noted in parentheses) coupled to a
specific receiver instance are assigned dynamically, and so the instance
numbers may not always match. The key thing to note is whether sampling or
polling is enabled on a port, and the sampling rates or polling intervals for the
receiver instance configured on each port.
Max Datagram Size shows the currently set value (typically a
default value, but this can also be set by the management station).
Number denotes the sampling/polling instance to which the receiver is coupled.
Dropped
Rate
Header
----------
40
128
1234567890
---
---
0
100
50
128
Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
|
Polling
Samples
|
Enabled
+
-------
---
0
Yes(1)
898703
No
0
No(3)
Interval
--------
---
60
30
0
13-39