Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Inbound Telnet
The switch currently responds to a request from the remote telnet client to
negotiate window size. However, some telnet clients do not request to nego­
tiate window size unless the switch's telnet server suggests that NAWS is
available.
This feature allows window size negotiation to occur with telnet clients that
support NAWS but do not try to use it unless it is suggested by the switch's
telnet server. The switch's telnet server will suggest to the telnet client that
NAWS is available.
Reconfigure Web Browser Access. In the default configuration, web
browser access is enabled.
Syntax: [no] web-management [listen <oobm | data | both>]
To disable web browser access:
ProCurve(config)# no web-management
To re-enable web browser access:
ProCurve(config)# web-management
Reconfigure the Console/Serial Link Settings. You can reconfigure one
or more console parameters with one console command.
7-8
Use the
no
version of the command to disable inbound HTTP
access.
The
listen
parameter is available only on switches that have a
separate out-of-band management port. Values for this
parameter are:
oobm
— inbound HTTP access is enabled only on
the out-of-band management port.
data
— inbound HTTP access is enabled only on
the data ports.
— inbound HTTP access is enabled on both
both
the out-of-band management port and on the data
ports. This is the default value.
Refer to Appendix G, "Network Out-of-Band Management" in
this guide for more information on out-of-band management.
The
parameter is not available on switches that do not
listen
have a separate out-of-band management port.