==========================- CONSOLE - MANAGER MODE -========================
System Name : ProCurve
System Contact :
System Location :
Inactivity Timeout (min) [0] : 0
Inbound Telnet Enabled [Yes] : Yes
Time Sync Method [None] : TIMEP
TimeP Mode [Disabled] : Disabled
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Actions->
Cancel
Figure 9-1. The System Information Screen (Default Values)
2. Press [E] (for Edit). The cursor moves to the System Name field.
3. Use [v] to move the cursor to the Time Sync Method field.
4. Use the Space bar to select SNTP, then press [v] once to display and move
5. Do one of the following:
Figure 9-2. Time Configuration Fields for SNTP with Broadcast Mode
Switch Configuration - System Information
Edit
Save
to the SNTP Mode field.
Use the Space bar to select the Broadcast mode, then press
move the cursor to the Poll Interval field, and go to step 6. (For
Broadcast mode details, refer to "SNTP Operating Modes" on
page 9-3.)
Time Sync Method [None] : SNTP
SNTP Mode [Disabled] : Broadcast
Poll Interval (sec) [720] :
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Use the Space bar to select the Unicast mode, then do the
following:
[>]
i. Press
to move the cursor to the Server Address field.
ii. Enter the IP address of the SNTP server you want the switch to
use for time synchronization.
SNTP: Viewing, Selecting, and Configuring
MAC Age Time (sec) [300] : 300
Web Agent Enabled [Yes] : Yes
Server Address :
Jumbo Max Frame Size [9216] : 9216
Jumbo IP MTU [9198] : 9198
Time Protocol Selection Parameter
– TIMEP
– SNTP
Help
– None
720
Time Protocols
[v]
to
9-7