AOR CU8232 Manual page 33

Remote control interface for the ar8000 hand portable radio receiver
Table of Contents

Advertisement

RF
Write and recall receive frequency to / from VFO.
The RF command is used to write a frequency to VFO. The input may be
specified in Hz or in MHz if the decimal point is used.
The format of the RF command being:
RFnnnnnnnnm0[ ]
or
RFnnnn.nnnnm[ ]
Note: "0" must always be used in the 1Hz place when using Hz input & "m" must
always be either 0 or 5 in the 10Hz position, any other number will be ignored.
Frequencies below 1.6 MHz (1600 kHz) are displayed as kHz.
For example:
150.3 MHz
input
1134 kHz
input
1691.0 MHz input
To recall the receive frequency of the current VFO, the RF[ ] command is used.
The response may look like RF0001134000[ ]
Related commands VA VB
(Hz)
(MHz)
RF150.2[ ] or RF150200000[ ]
RF1.134[ ] or RF1134000[ ]
RF1691.[ ] or RF1691000000[ ]