<When the AC power is off> (The power cord is not plugged into the wall outlet.)
Connect the power cord to NEC Express5800/ft series in the following order:
1
Connect the power cord to the AC inlet B (for Group1)
2
Connect the power cord to the AC inlet A (for Group2)
3
Confirm that the POWER switch of the PCI module for Group1 is illuminated.
4
Make sure that the two BMC status LEDs for PCI modules (for Group1/for Group2) are
turned off.
IMPORTANT:
While the BMC status LED is red and blinking, do not start the ft series setup. Otherwise the
setup may not be done properly.
Preparation is now completed. Start the ft series setup.
<When the AC power is on> (The power cord is plugged to the wall outlet and the main unit's
power is off)
1
Check the lamp of the PCI module's POWER switch.
If the PCI module for Group1's POWER switch is lit, PCI module for Group1 is
primary. Preparations are complete. Start the ft series setup.
If the PCI module for Group2's POWER switch is lit, the PCI module for Group1
is secondary. Continue to step (2). Make PCI module for Group1 the primary
module.
Rack-mount model
Windows Setup 3-13
AC inlet B
(for Group1)
AC inlet A
(for Group2)