NEC Express 5800 User Manual page 96

Hide thumbs Also See for Express 5800:
Table of Contents

Advertisement

4-22
Procedures after Completion of Installation
Because minimum non-communication time is momentary regardless of size of the memory
installed, it will not be considered as non-communication. Maximum non-communication time
by the memory size is as follows:
Memory size
256MB
512MB
1GB
2GB
3GB
6 GB
This setup program sets the following Windows registry:
Windows XP/Windows NT/Windows 2000/Windows Server 2003:
Registry key:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters
Values:
TcpMaxConnectRetransmissions
Type:
REG_DWORD
Set value: 5
Values:
TcpMaxDataRetransmissions
Type:
REG_DWORD
Set value: 8
Values:
TcpMaxConnectREsponseRetransmissions
Type:
REG_DWORD
Set value: 5
Windows 95/98/Me:
Registry key:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\VxD\MSTCP
Values:
MaxConnectRetries
Type:
String
Set value: 5
Values:
MaxDataRetries
Type:
String
Set value: 8
Non-communication time
About 3.1 seconds
About 6.2 seconds
About 12.3 seconds
About 24.7 seconds
About 36.3 seconds
About 47.0 seconds

Advertisement