xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
Success.
DGS-3620-28SC:admin#
87-9
config sflow analyzer_server
Description
This command is used to configure the sFlow analyzer server information. More than one collector
with the same IP address can be specified if the UDP port numbers are unique.
Format
config sflow analyzer_server <value 1-4> {timeout [<sec 1-2000000> | infinite] |
collectoraddress [<ipaddr> | <ipv6addr>] | collectorport <udp_port_number 1-65535> |
maxdatagramsize <value 300-1400>}(1)
Parameters
<value 1-4> - Enter the analyser server ID used here. This value must be between 1 and 4. The
switch supports 4 different analyser servers at the same time. Each sampler or poller can
select a server ID (1, 2, 3, or 4) to send the samples.
timeout - (Optional) Specify the time (in seconds) remaining before the sample is released and
stops sampling. When the analyzer_server times out, all of the flow_samplers and
counter_pollers associated with this analyzer_server will be deleted. If it is specified as infinite,
the server will never be timeout.
<sec 1-2000000> - Specify the time out value, in seconds, between 1 and 2000000.
infinite - Specify to never time out.
collectoraddress - (Optional) Specify the IP address of the server.
<ipaddr> - Specify the IP address of the server. If set to 0, sFlow packets will not be sent to
this server.
<ipv6addr> - Specifies the IPv6 used.
collectorport - (Optional) Specify the destination port for sending sflow datagrams.
<udp_port_number 1-65535> - Specify the destination port for sending sflow datagrams. The
number is between 1 and 65535.
maxdatagramsize - (Optional) Specify the maximum number of data bytes that can be packed in
a single sample datagram.
<value 300-1400> - Specify the maximum number of data bytes that can be packed in a
single sample datagram. The values is between 300 and 1400.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the sFlow analyzer server information:
DGS-3620-28SC:admin#config sflow analyzer_server 1 collectoraddress 10.90.90.9
Command: config sflow analyzer_server 1 collectoraddress 10.90.90.9
Success.
DGS-3620-28SC:admin#