Other settings

Initializing the M-300's internal memory
The following items will be initialized, returning them to the
factory settings:
• System settings
• Mixer parameters
• Scene memories
• All USER library data
• User settings
When you initialize the internal memory, all data that had
been saved in memory will be lost.
If you want to keep this data, you must save it to USB
memory as a project file (p. 156) and user file (p. 131) to USB
memory.
1.
In the SETUP section, hold down [SYSTEM] and turn the
power on.
fig.SystemConfig.eps
The M-300 will start up in SYSTEM CONFIG MODE, and the
SYSTEM CONFIG screen will appear.
2.
Press [F1 (Factory Initialize)].
fig.FactoryInitConfirm.eps
A message will ask you to confirm the operation.
3.
Press [F8 (INIT)].
Initialization will begin.
Do not turn off the power until the initialization is
completed.
4.
Turn off the power.
164
Clearing the ADMIN password
If you've forgotten the ADMIN password, you can use the
following procedure to clear the ADMIN password.
If you want to reset the password, you can do so after this
procedure as described in "Changing the password of user
settings" (p. 132).
1.
In the SETUP section, hold down [SYSTEM] and turn the
power on.
ig.SystemConfig.eps
The M-300 will start up in SYSTEM CONFIG MODE, and the
SYSTEM CONFIG screen will appear.
2.
Press [F2 (Clear Password)].
fig.ClearAdminPwdConfirm.eps
A message will ask you to confirm the operation.
3.
Press [F8 (CLEAR)].
The ADMIN password will be cleared.
4.
Turn off the power.
You can also clear the ADMIN password by holding down both
the [DISP] button of the USER section and the [SOLO CLEAR]
button of the MONITOR section while you switch on the power.