Roland RSS M-300 Owner's Manual page 45

Live mixing console
Table of Contents

Advertisement

For the following channels, the preamp area will show only
the Ø (phase) button:
• Channels to which no input port is patched
• Channels to which a port that has no preamp (such as
an internal port) is patched
2
ATT (Attenuator)
fig.ScrChATT.eps
1
2
OL (Overload) indicator
1
This will light red when the output of the attenuator exceeds
the OVER Lev setting specified in the METER SETUP popup
(p. 96).
ATT knob
2
This adjusts the input level of the channel in a range of -48.0
dB– +24.0 dB.
Normally, you should use the preamp gain to adjust the
input level of the channel, and leave the attenuator at 0 dB. It
is convenient to use the attenuator in the following types of
cases:
• When you've patched a port that has no preamp gain,
such as an internal port
• When you've allowed plenty of head margin to avoid
overloading the preamp's AD converter, and want to
boost the level at the channel
3
HPF (High-pass filter)
fig.ScrChFilt.eps
3
1
2
HPF button
1
This turns the HPF on/off.
FREQ knob
2
This adjusts the HPF frequency in a range of 20 Hz–20.0 kHz.
OL (Overload) indicator
3
This will light red when the output of the filter exceeds the
OVER Lev setting specified in the METER SETUP popup (p.
96).
Input channel operations
4
Gate/expander
fig.ScrChGate.eps
4
1
2
5
3
GATE button
1
This turns the gate/expander on/off.
IN meter
2
This shows the input level of the gate/expander. For stereo-
linked channels, two meters (L and R) will be shown.
GR meter
3
This shows the amount of gain reduction for the gate/
expander.
OL (Overload) indicator
4
This will light red when the output of the gate/expander
exceeds the OVER Lev setting specified in the METER SETUP
popup (p. 96).
THRE knob
5
This adjusts the threshold level of the gate/expander in a
range of -80.0 dB–0.0 dB.
For details, refer to "Gate/expander operations" (p. 68).
Compressor
5
fig.ScrChComp.eps
4
1
2
5
3
COMP button
1
This turns the compressor on/off.
IN meter
2
This shows the input level of the compressor. For stereo-
linked channels, two meters (L and R) will be shown.
GR meter
3
This shows the amount of gain reduction for the compressor.
OL (Overload) indicator
4
This will light red when the output of the compressor
exceeds the OVER Lev setting specified in the METER SETUP
popup (p. 96).
THRE knob
5
This adjusts the threshold level of the compressor in a range
of -40.0 dB–0.0 dB.
For details, refer to "Compressor operations" (p. 74).
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents