Dynamics
Selecting the key-in signal for the
compressor
The key-in signal used by the compressor is taken from the post-
gate point of the channel itself or any of the following sources:
• CH1–32 Direct out
• AUX1–8, MTX1–4, MAIN L/R/C output
• REAC A IN1–40
• REAC B IN1–40
• CONSOLE IN1–12
ig.CompKeyInFlow.eps
GATE/
PHASE
ATT
HPF
EXP
- SELF POST GATE
- CH 1-32 DIRECT OUT
KEY-IN
- REAC A IN1–40
FILTER
- REAC B IN1–40
- CONSOLE IN1–12
To select the key-in signal, use the KEY-IN SELECT popup.
1.
Move the cursor to the KEY-IN SELECT popup button, and
press [ENTER].
fig.PopKeyInguide2.eps
1
2
The KEY-IN SELECT popup will appear.
1
Current key indication
This indicates the current key.
2
Dynamics type indication
This indicates the type of dynamics to which the KEY-IN
SELECT popup applies.
3
Key-in signal select buttons
These buttons select the channel that will be used as the
key-in signal.
The function buttons have the following operations:
[F1 (CH1-32)]
Displays CH1–32 as the key-in signal select
buttons.
[F2 (BUS)]
Displays AUX1–8, MTX1–4, and MAIN L/R/C as
the key-in signal select buttons.
[F3 (REAC A)]
Displays REAC A IN1–40 as the key-in signal
select buttons.
[F4 (REAC B)]
Displays REAC B IN1–40 as the key-in signal
select buttons.
[F5 (CONSOLE)]
Displays CONSOLE IN1–12as the key-in signal
select buttons.
76
COMP
KEY-IN
SOLO
TO SOLO
3
[F6 (SELECT SELF)]
Selects the channel itself as its own key-in
signal.
[F8 (CLOSE)]
Closes the popup.
2.
Move the cursor to the desired key-in signal select
button, and press [ENTER] to select it.
3.
Press [F8 (CLOSE)] to close the popup.
If you want the channel itself to be its own key-in signal, press
[F6 (SELCT SELF)].
Using key-in filter
1.
Access the COMPRESSOR popup.
fig.PopComp.eps
2.
Use the filter type select buttons to select the filter type.
3.
Use the FREQ/Q knobs, in the KEY-IN FILTER section, to
adjust the filter.
4.
Use the ON button, in the KEY-IN FILTER section, to turn
the filter on.
If you turn [F7 (KEY-IN SOLO)] on, you can hear the output signal
of the key-in filter via the M-300's monitor output.
[F7 (KEY-IN SOLO)] will automatically be cancelled when you
close the COMPRESSOR popup.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents