D
FRU Replacement
This section details replacement information for various QLogic 12000 components.
For replacement parts, contact QLogic or an approved reseller.
NOTE:
If part of a standard operating procedure, add replacement identification
tags to both the rack and the FRU hardware to ensure that the warranty is
transferred to the replacement part(s).
NOTE:
If the FRU being replaced is in an active chassis (i.e, hot swapping), please
replace the FRU within 2 minutes to maintain thermal integrity.
QLogic 12200
NOTE:For an externally-managed 12200, refer to the Fast Fabric User
Guide for update information.
Chassis Replacement
FRU part number:
Standard chassis: 12200-BS01
Reversed airflow/AC power inlets: 12200-BS02
Removal Procedures
1.
Power down the switch by unplugging AC power.
2.
Remove all applicable IB, Ethernet and Serial cables. Set these aside for
reinstalling the replacement switch.
3.
Remove the switch from the rack. Keep all rail hardware installed in the rack.
4.
Remove the hat rails from the switch. Set these aside for for reinstalling the
replacement switch.
Replacement Procedures
1.
Install the hat rails to the switch.
2.
Rack mount the switch in the existing rails on the rack.