2. INSTALLATION

2.2 Installation direction and clearances

CAUTION
(1) Installation of one servo amplifier
10mm
(0.4 in.)
or more
(2) Installation of two or more servo amplifiers
Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
(3) Others
Install the servo amplifier on a perpendicular wall in the correct vertical direction.
The equipment must be installed in the specified direction. Otherwise, a fault may
occur.
Leave specified clearances between the servo amplifier and control box inside walls
or other equipment.
Control box
40mm
(1.6 in.)
or more
Servo amplifier
MITSUBISHI
10mm
(0.4 in.)
MELSERVO
OPEN
CN1A
CN1B
or more
CNP1
CNP2
CNP3
40mm
(1.6 in.)
or more
100mm
(4.0 in.)
or more
MITSUBISHI
10mm
OPEN
(0.4 in.)
or more
CNP1
Control box
Wiring clearance
70mm
(2.8 in.)
Control box
1mm
(0.04 in.)
or more
MITSUBISHI
MELSERVO
MELSERVO
OPEN
CN1A
CN1B
CN1A
CN1B
CNP2
CNP1
CNP2
CNP3
CNP3
40mm
(1.6 in.)
or more
2 - 2
Top
Bottom
10mm
(0.4 in.)
or more