Test Operation Mode; Mode Change - Mitsubishi Electric Melservo-J2-JR SERIES Instruction Manual

General-purpose ac servo general-purpose interface mr-j2-03a5
Table of Contents

Advertisement

6. DISPLAY AND OPERATION

6.8 Test operation mode

CAUTION
6.8.1

Mode change

Call the display screen shown after power-on. Choose jog operation/motor-less operation in the following
procedure:
The test operation mode is designed to confirm servo operation and not to confirm
machine operation. In this mode, do not use the servo motor with the machine.
If any operational fault has occurred, stop operation using the forced stop (EMG)
signal.
POINT
The Servo Configuration software is required to perform positioning
operation.
Press MODE once.
Press UP three times.
Press SET for more than
2s.
When this screen
appears, jog feed can
be performed.
Flickers in the test operation mode.
6 - 12
Press UP five times.
Press SET for more than 2s.
When this screen is displayed,
motor-less operation can be
performed.