2. INSTALLATION
2.1 Installation direction and clearances
CAUTION
MR-JE-40A to MR-JE-100A have a regenerative resistor on their back face. The regenerative resistor
generates heat of 100 °C higher than the ambient temperature. Please fully consider heat dissipation,
installation position, etc. when mounting it.
(1) Installation clearances of the servo amplifier
(a) Installation of one servo amplifier
Cabinet
10 mm
or more
The equipment must be installed in the specified direction. Otherwise, it may
cause a malfunction.
Leave specified clearances between the servo amplifier and the cabinet walls or
other equipment. Otherwise, it may cause a malfunction.
40 mm
or more
Servo
amplifier
10 mm
or more
40 mm
or more
Cabinet
Wiring allowance
80 mm
or more
2 - 2
Top
Bottom