Speed Control Mode - Mitsubishi Electric Melservo-J2-JR SERIES Instruction Manual

General-purpose ac servo general-purpose interface mr-j2-03a5
Table of Contents

Advertisement

4. OPERATION
4.2.3

Speed control mode

(1) Power on
(a) Switch off the servo on (SON) signal.
(b) When main circuit power/control circuit power is switched on, "r (motor speed)" appears on the
parameter unit.
(2) Test operation
Using jog operation in the "test operation mode" of the Parameter unit, make sure that the servo motor
operates. (Refer to Section 6.8.2.)
(3) Parameter setting
Set the parameters according to the structure and specifications of the machine. Refer to Chapter 5 for
the parameter definitions and to Sections 6.5 for the setting method.
Parameter
No. 0
Select the control mode
No. 2
Auto tuning
No. 8
Internal speed command 1
No. 9
Internal speed command 2
No. 10
Internal speed command 3
No. 11
Acceleration time constant
No. 12
Deceleration time constant
S-pattern acceleration/deceleration
No. 13
time constant
After setting the above parameters, switch power off once. Then switch power on again to make the
set parameter values valid.
(4) Servo on
Switch the servo on in the following procedure:
(a) Switch on main circuit/control power.
(b) Switch on the servo on signal (SON) (short SON-SG).
When placed in the servo-on status, the servo amplifier is ready to operate and the servo motor is
locked.
(5) Start
Using speed selection 1 (SP1) and speed selection 2 (SP2), choose the servo motor speed. Turn on
forward rotation start (ST1) to run the motor in the forward rotation (CCW) direction or reverse
rotation start (ST2) to run it in the reverse rotation (CW) direction. At first, set a low speed and check
the rotation direction, etc. If it does not run in the intended direction, check the input signal.
On the status display, check the speed, load factor, etc. of the servo motor.
When machine operation check is over, check automatic operation with the host controller or the like.
This servo amplifier has a real-time auto tuning function under model adaptive control. Performing
operation automatically adjusts gains. The optimum tuning results are provided by setting the
response level appropriate for the machine in parameter No. 2.
Name
Setting
1000
1500
2000
1000
4 - 4
2
First digit
: Speed control mode
First digit
: Middle response (initial value) is selected.
104
Second digit : Ordinary machine
Third digit
: Used
Set 1000r/min.
Set 1500r/min.
Set 2000r/min.
Set 1000ms.
500
Set 500ms.
0
Not used