Mitsubishi Electric Melservo-J2-JR SERIES Instruction Manual page 96

General-purpose ac servo general-purpose interface mr-j2-03a5
Table of Contents

Advertisement

5. PARAMETERS
(2) Setting for use of AD75P
The AD75P also has the following electronic gear parameters. Normally, the servo amplifier side
electronic gear must also be set due to the restriction on the command pulse frequency (differential
500kpps, open collector 200kpps).
AP: Number of pulses per motor revolution
AL: Moving distance per motor revolution
AM: Unit scale factor
AP75P
Command
value
Control
unit
Electronic gear setting example for use of AD75P
Input system
Max. input pulse frequency
Servo amplifier
Feedback pulse/revolution
Electronic gear (CMX/CDV)
Command pulse frequency (Note 1)
Number of pulses per servo motor revolution as viewed from AD75P 4000pulse/rev
AD75P
Electronic gear
Note: 1. Command pulse frequency at rated speed
2. Assuming that AP=8192 and AL=8000, the command unit amount per motor revolution is 8000 pulses/rev, which
makes positioning data setting easier.
3. In the case where the ballscrew lead is 10mm.
AP
AL
AM
Command
pulse
Electronic gear
Rated Servo Motor Speed
Minimum command unit
1pulse
Minimum command unit
0.1 m(Note 3)
Servo amplifier
CMX
+
Deviation
CDV
counter
-
Electronic gear
Feedback pulse
AP
AL
AM
AP
AL
AM
5 - 19
Servo motor
3000r/min
Open collector
Differential line driver
200kpps
500kpps
8192pulse/rev
125/256
1/1
200kpps
409.6kpps
8192pulse/rev
1
1(Note 2)
1
1(Note 2)
1
1(Note 2)
4000
8192
1000
1000
100
100