12. OPTIONS AND AUXILIARY EQUIPMENT
(b) Cable clamp fitting (AERSBAN- SET)
Generally, the earth of the shielded cable may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an earth plate as shown below.
Install the earth plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the earth plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the earth plate.
Srip the cable sheath of
athe clamped area.
Outline drawing
Earth plate
2- 5(0.20) hole
installation hole
(Note)M4 screw
Note: Screw hole for grounding. Connect it to
the earth plate of the control box.
Type
AERSBAN-DSET
AERSBAN-ESET
cutter
cable
17.5(0.69)
22(0.87)
6
35(1.38)
(0.24)
A
B
C
Accessory Fittings
100
86
30
(3.94)
(3.39)
(1.18)
70
56
(2.76)
(2.20)
Clamp section diagram
Clamp Fitting
clamp A: 2pcs.
clamp B: 1pc.
12 - 14
Cable
Cable clamp
(A,B)
External conductor
[Unit: mm]
([Unit: in.])
Clamp section diagram
L or less
10(0.39)
L
70
A
(2.76)
45
B
(1.77)
Earth plate