11. CHARACTERISTICS

11. CHARACTERISTICS

11.1 Overload Protection Characteristics

An electronic thermal relay is built in the servo amplifier to protect the servo motor and servo amplifier
from overloads. The operation characteristics of the electronic thermal relay are shown below. Overload 1
alarm (A. 50) occurs if overload operation performed is above the electronic thermal relay protection curve
shown below. Overload 2 alarm (A. 51) occurs if the maximum current flew continuously for several
seconds due to machine collision, etc. Use the equipment on the left-hand side area of the continuous or
broken line in the graph.
If load is applied at stop (during servo lock), 70% of the rated torque must not be exceeded.
HC-AQ Series
1000
During rotation
100
During stop
10
1
0.1
0
50
100
150
200
250
300
Load ratio [%]
Fig 11.1 Electronic Thermal Relay Protection Characteristics
11 - 1