3. SIGNALS AND WIRING
(2) Fitting of earth (E) terminal (AERSBAN-JR)
As shown below, fit the earth (E) terminal to the bottom or top of the servo amplifier.

3.10 Instructions for the 3M Connector

When fabricating an encoder cable or the like, securely connect the shielded external conductor of the cable
to the ground plate as shown in this section and fix it to the connector shell.
External conductor
Strip the sheath.
Positioning boss
Sheath
Screw
Screw
Ground plate
Earth (E) terminal
AERSBAN-JR
M4 screw
Core
External conductor
Pull back the external conductor to cover the sheath
Cable