reached before the specified status is obtained or if an invalid status results, the error action is
executed. For details on invalid statuses, see
GOTO Parameter" (page
{DUPLEX|SUSPEND|SIMPLEX|SUSPVS|HOLD}
Specifies the status of the copy group that is specified in the GOTO parameter of the YKEWAIT
command. After all copy pairs in the copy group have changed to the specified status, the
processing terminates normally. For details on this value, see the description of the GOTO parameter
in
"YKEWAIT Command" (page
timeout-value ~ <numeric characters> ((0 to 9999))
Specifies (in minutes) the timeout value that is specified in the TIMEOUT parameter in the YKEWAIT
command. If you omit this value, the value specified for the WAITTIMEOUT parameter in the
YKMONOPT file is used. For details on this value, see the description of the TIMEOUT parameter
in
"YKEWAIT Command" (page
RESYNC(copy-group-ID,command-wait-time[,command-parameter])
Executes the YKRESYNC command with the specified command parameter on the specified copy
group after the specified command wait time elapses.
command-wait-time ~ <numeric character>((0 to 9999))
Specifies in minutes the wait time before the YKRESYNC command is executed.
command-parameter ~ <up to 256 characters of command parameter string>
Specifies the YKRESYNC command parameters. The STEM and MSG parameters are ignored even
if they are specified. For details on the specifiable parameters, see the description of parameters
in
"YKRESYNC Command" (page
SUSPEND(copy-group-ID[,command-parameter])
Executes the YKSUSPND command with the specified command parameters on the specified copy
group.
command-parameter ~ <up to 256 characters of command parameter string>
Specifies the parameters of the YKSUSPND command. The STEM and MSG parameters are ignored
even if they are specified. For details on the specifiable parameters, see the description of
parameters in
"YKSUSPND Command" (page
In addition to the parameters that can be specified in the YKSUSPND command, the following
OFFSET parameter can also be specified:
OFFSET(mmmm:ss)
Executes a suspension using the ATTIME suspend function at the time obtained by adding the
offset value to the YKSUSPND command execution time. The ATTIME parameter is valid when it
is specified at the same time as the YKSUSPND command.
If you specify OFFSET, you must specify the WAITFOR action of the SUSPEND specification for the
subsequent action. If the WAITFOR action of the SUSPEND specification is not specified for the
subsequent action and the OFFSET value is greater than the cycle time, during the next cycle, the
SUSPEND action of the OFFSET specification will be executed.
mmmm ~ <numeric characters>((0000 to 9999))
Specifies the offset value in minutes.
ss ~ <numeric characters>((00 to 99))
Specifies the offset value in seconds.
DELETE(copy-group-ID)
Executes the YKDELETE command on the specified copy group.
MAKE(copy-group-ID[,command-parameter])