Table 127 YKQUERY Command Return Code List (continued)
Return Code
16
20
24
32
36
40
44
48
128

YKRECVER Command

Applies to Continuous Access Synchronous for Mainframe, Continuous Access Synchronous for
Mainframe with the HyperSwap attribute, Continuous Access Asynchronous for Mainframe, and
Continuous Access Journal for Mainframe.
Format
YKRECVER
STEM(stem-name-1)
1
MSG(stem-name-2)
1
[
DEVN(p-vol-device-number,s-vol-device-number)]
1
Function
This command is a TSO/E command called from REXX scripts.
When copy pair operations from the primary site are disabled due to failure or other reasons, this
command dissolves a copy pair for the specified copy group from the secondary site.
When you use this command to dissolve a copy pair, the volume on the secondary site assumes
the SIMPLEX status, but the volume on the primary site takes the SUSPER status. Note, however,
Meaning
P-VOL is in an inconsistent status. This return code appears, for example, when, in
an BC copy group, the P-VOL for the copy pair for which processing is attempted
already belongs to a copy pair with a third S-VOL other than the S-VOL defined
for the copy group.
S-VOL is in an inconsistent status. This return code appears, for example, when the
status of the P-VOL is SIMPLEX, and the status of the S-VOL is anything other than
SIMPLEX
An error occurred when the suspend processing was performed by using the
CAJ ATTIME suspend function.
The status of the CAJ copy pair was invalid when the suspend processing was
performed by using the CAJ ATTIME suspend function.
The suspend processing has started because the timeout period had elapsed
when the CAJ ATTIME suspend function was executed.
I/O errors were encountered.
A change in an I/O configuration definition was detected.
An invalid or unknown element was found in the configuration.
An inconsistency was detected between a copy group definition and an actual
copy group.
An error occurred while a REXX variable was being written.
Terminating due to processing errors. This return code appears, for example, in
the following cases:
A GETMAIN error has occurred.
For CG containers specified by EXCTG ID, journal groups have not yet been
registered in EXCTG.
Terminating due to invalid parameters. This return code appears, for example,
when the copy pair corresponding to the device number specified with the DEVN
parameter is not found.
The command terminated abnormally. The user does not have permission to execute
this command.