HP StorageWorks P9000 Reference Manual page 211

Business continuity manager software reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

at that moment. If the status is the same as the one specified in the GOTO parameter, the command
terminates normally (return code = 0). If not, it terminates abnormally with the return code 4.
If 0 is specified in TIMEOUT parameter, it looks at the status of the copy group immediately, and
then returns as described previously.
For CG containers specified by EXCTG ID, if this time value elapses before all journal groups are
registered in EXCTG, the YKZ298W message is output and the YKEWAIT command terminates
abnormally with return code 4. If the YKZ298W message is output, the REXX variable is disabled
(the same state as before the YKEWAIT command was executed).
NOINVALIDCHECK
Processing continues even when the status changes to anything other than the status specified by
the GOTO parameter (invalid statuses). If this parameter is specified, and the status does not change
to that specified in the GOTO parameter, command processing will continue until the timeout time
specified in the TIMEOUT parameter is reached.
The invalid statuses in
parameter. The table shows an invalid status for each value specifiable in the GOTO parameter.
Table 1 12 Invalid Status for Each Value Specifiable in the GOTO Parameter
Value of GOTO Parameter
DUPLEX
SUSPEND
SIMPLEX
SUSPVS
HOLD
SWAPPING
When the command waits for copy pairs in the CG container specified by EXCTG ID to reach
DUPLEX status, it first waits for all journal groups in the CG container specified by EXCTG ID to
be registered in EXCTG. If an error is detected during EXCTG registration, the YKZ297E message
is output and the command terminates abnormally with return code 44.
When the command monitors the status of a copy pair in an BC copy group to which the CAJ
ATTIME suspend time has been set, the check operation differs depending on whether the
NOINVALIDCHECK parameter is specified:
If the NOINVALIDCHECK parameter is not specified
The status of the CAJ copy pair at the time of BC copy pair suspension will be checked. If an
error is detected, the YKZ407E message, YKZ408E message, or YKZ409E message is output
and the command terminates abnormally with return code 24.
If the NOINVALIDCHECK parameter is specified
The status of the CAJ copy pair at the time of BC copy pair suspension will not be checked.
DEVN(p-vol-device-number,s-vol-device-number) ~ <4-digit hexadecimal number, 4-digit
hexadecimal number>
Specify the device number of the copy pair (P-VOL and S-VOL) to operate.
Table 1 12 (page 211)
Invalid Statuses
SIMPLEX, SUSPCU, SUSPER, TRANS, SUSPVS, HOLDER, NODELTA,
CONSLOST, or INVALID
SIMPLEX, SUSPER, SUSPCU, HOLD, HOLDER, HOLDTRNS, NODELTA,
CONSLOST, or INVALID statuses.
SUSPER, SUSPCU, HOLDER, CONSLOST, or INVALID statuses.
SUSPER, SIMPLEX, SUSPCU, HOLD, HOLDER, HOLDTRNS, NODELTA,
CONSLOST, or INVALID statuses.
SIMPLEX, SUSPER, SUSPCU, HOLDER, NODELTA, or INVALID statuses.
SIMPLEX, HOLD, HOLDER, HOLDTRNS, NODELTA, CONSLOST, or
INVALID statuses.
differ depending on the value specified in the GOTO
Command details