SSN(storage system-serial-number) ~ <from 5 to 12 alphanumeric characters>
If this parameter is specified, out of the logical paths within the path set stored in the path set
structure specified for the STEM parameter, inter-CU logical paths will be acquired in all cases
where the paths treat CUs within storage systems (that have the serial number specified by this
parameter) as RCUs, and inter-DKC logical paths will be acquired in all cases where the paths
treat the storage system (that has the serial number specified by this parameter) as the secondary
storage system.
If neither this parameter nor any other parameters are specified, the command acquires all logical
paths.
SCU(cu-number) ~ <2-digit hexadecimal number>
If this parameter is specified, out of the logical paths within the path set stored in the path set
structure specified for the STEM parameter, inter-CU logical paths will be acquired in all cases
where the CU number of the RCU matches the value specified for this parameter. Inter-DKC logical
paths are not affected by this parameter.
If neither this parameter nor any other parameters are specified, the command acquires all inter-CU
logical paths.
{FORWARD|REVERSE}
Specify the direction of the logical path whose status you want to acquire.
If neither is specified, the command will acquire the status of a bidirectional logical path.
FORWARD
The command acquires the status of forward logical paths that are identified in the path set stored
in the path set structure specified by the STEM parameter, each of which extends from the initiator
node defined by stem-name-specified-in-STEM-parameterPATH.n.Pri to the target node defined
by stem-name-specified-in-STEM-parameterPATH.n.Sec.
REVERSE
The command acquires the status of the reverse logical paths that are identified in the path set
stored in the path set structure specified by the STEM parameter. Each path is a reverse logical
path from the initiator node defined by stem-name-specified-in-STEM-parameterPATH.n.Sec to
the target node defined by stem-name-specified-in-STEM-parameterPATH.n.Pri.
RESTRUCT
If the port information is set on the storage system, the command sets the port information on the
storage system to the REXX variable.
TYPE({CU|DKC})
This parameter specifies the type (inter-CU logical path or inter-DKC logical path) of the logical
path for which the status is to be acquired.
If neither this parameter nor any other parameters are specified, the command acquires the status
for all logical paths.
CU
Out of the logical paths within the path set stored in the path set structure specified by the STEM
parameter, the status is acquired for the logical paths that have CU set for
stem-name-specified-in-STEM-parameterPATH.n.type.