The details for this sample script are as follows:
/*
/*
*) When the cause of a HyperSwap is a DKC failure, execute this */
/*
sample script twice.
/*
When execution for a DKC maintenance or second execution for */
/*
a DKC failure, before using this sample script, change the
/*
status of the MYTCHS copy pair to Swapping that direction
/*
is the primary site to the secondary site.
/*
1) Call YKLOAD to load a configuration definitions.
/*
2) Check whether the cause of a HyperSwap was a DKC maintenance */
/*
or a failure.
/*
*) When first execution for a DKC failure, go to steps 3 and 4. */
/*
When execution for a DKC maintenance or second execution for */
/*
a DKC failure, go to steps 5 and 6.
/*
3) Delete the MYUR1 copy pair.
/*
4) Make the MYUR1 copy pair, exit this sample script, and then
/*
re-execute this sample script again.
/*
5) Suspend the MYUR2 copy pair.
/*
6) Execute a DeltaResync on the MYUR1 copy pair.
/*
*) After using this sample script, resync MYTCHS.
/*
/**********************************************************************/
/* Sample script begins. */
say "#-- BEGIN YKDEMO09."
address TSO "YKENV"
call "YKLOAD" "STEM(DEMO_INFO.MYTCHS.) PREFIX(BCM.DEMO) GROUP(MYTCHS)",
/*
* Check the return code of YKLOAD.
*/
if result /= 0
then do
call printErrorMessage
exit
end
else
nop
call "YKLOAD" "STEM(DEMO_INFO.MYUR1.) PREFIX(BCM.DEMO) GROUP(MYUR1)",
/*
* Check the return code of YKLOAD.
*/
if result /= 0
then do
call printErrorMessage
exit
end
else
nop
call "YKLOAD" "STEM(DEMO_INFO.MYUR2.) PREFIX(BCM.DEMO) GROUP(MYUR2)",
/*
* Check the return code of YKLOAD.
*/
if result /= 0
then do
call printErrorMessage
294 CLI Commands
"DAD(PRIM) MSG(DEMO_MSG.) ROUTE(DEMORLST)"
"DAD(PRIM) MSG(DEMO_MSG.)"
"DAD(PRIM) MSG(DEMO_MSG.)"
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/
*/