HP StorageWorks P9000 Reference Manual page 228

Business continuity manager software reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

NOTE:
If ONLINE(YES) is specified, volume corruption might occur because a copy pair can be
made even if the S-VOL is being used. Thus, consideration with respect to volume operation
is required, such as limiting operation to periods when the S-VOL is not being used.
If transition to HOLD status is not performed, this might indicate an environment in which
differentials cannot be maintained in the journal. Check the number of TrueCopy copy pairs
sharing P-VOL with the specified copy pairs, the number of CAJ copy pairs sharing S-VOL
with the specified copy pairs, and the status of copy pairs.
Because the EXCTG registration processing is performed asynchronously with the YKMAKE
command, an error might occur during EXCTG registration even if the YKMAKE command
terminates normally. Therefore, after executing the YKMAKE command on a CG container
specified by EXCTG ID, execute either the YKEWAIT GOTO(DUPLEX) command or the
YKQUERY command to check if an error occurred during EXCTG registration.
If the YKMAKE command is executed for a copy group container with an EXCTG ID, EXCTG
registration might fail with error code 3688 even if a copy pair is successfully created. If error
code 3688 occurs when the YKMAKE, YKQUERY, or YKEWAIT command is executed, re-execute
the YKMAKE command specifying SELECT(COND) to register the journal group in the EXCTG.
Return Codes
"Return codes when the YKMAKE command terminates" (page 228)
returned when the YKMAKE command terminates.
Table 123 Return codes when the YKMAKE command terminates
Return Code
-4095 to -4040
-3
-1
0
4
32
36
40
44
48
128
228 CLI Commands
Meaning
The command terminated abnormally, possibly because the user SVC routine has
not been included properly.
The module cannot be loaded. Possible causes are as follows:
The library dataset has not been linked.
The module is protected by the RACF program control function.
An interruption occurred during execution.
The command completed normally.
Since a volume with an invalid status was found in the copy group, processing for
the volume will be skipped.
I/O errors were encountered.
A change in an I/O configuration definition was detected.
Invalid or missing data in a REXX variable.
An error occurred while a REXX variable was being written.
Terminating due to processing errors.
Terminating due to invalid parameters. This return code appears, for example,
when the copy pair corresponding to the device number specified with the DEVN
parameter is not found.
The command terminated abnormally. The user does not have permission to execute
this command.
lists the return codes to be

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents