Item No.
U631
Setting communication control 2
Description
Makes settings regarding fax transmission.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
ECM TX
ECM RX
CED FREQ.
Setting ECM transmission
To be set to OFF when reduction of transmission costs is of higher priority than image quality.
This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line.
1. Select the setting using the cursor up/down keys.
Display
ON
OFF
* : Initial setting: ON
2. Press the start key. The setting is set.
Setting ECM reception
To be set to OFF when reduction of transmission costs is of higher priority than image quality.
This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line.
1. Select the setting using the cursor up/down keys.
Display
ON
OFF
* : Initial setting: ON
2. Press the start key. The setting is set.

Setting the frequency of the CED signal

Sets the frequency of the CED signal. Used as one of the measures to improve transmission per-
formance for international communications.
1. Select the setting using the cursor up/down keys.
Display
2100
1100
* : Initial setting: 2100
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Sets ECM transmission.
Sets ECM reception.
Sets the frequency of the CED signal.
Description
ECM transmission is enabled.
ECM transmission is disabled.
Description
ECM reception is enabled.
ECM reception is disabled.
Description
2100 Hz
1100 Hz
1-3-56