5045-001

Transfer Drum Solenoid

See Assembly 29-5.
1. Remove the transfer drum and holder assembly.
2. Remove the two springs from the attraction roller holder.
3. Remove the two springs from the discharge roller holder.
4. Remove the two extension springs holding the one end of the
transfer drum sheet to the transfer drum.
Note: Use cotton gloves to handle the transfer sheet.
5. Rotate the drum while peeling the sheet off the drum surface.
6. Pry off the two round plastic screw caps from the gripper
assembly.
7. Remove the two screws from the gripper assembly and lay the
assembly back. Do not remove the transfer sheet from the
gripper assembly. Also, be careful to not damage the transfer
sheet.
8. Rotate the drum to expose the solenoid connector and
disconnect the connector.
9. Rotate the drum to expose the solenoid mounting screws.
Remove the two screws from the solenoid and remove the
solenoid from the drum.
Repair Information 4-57