5045-001

Error (126/131) Transfer Drum Motor Failure

FRU
1
Poor connection
2
Door switch
3
Drum motor
Mechanical
controller PCB
4
Transfer drum
top sensor
DC controller
PCB

Error (130) Service Motor Error

FRU
1
Mechanical
controller PCB
2-22
Action
Check the connection on the mechanical controller
PCB connector J2015. Reconnect it.
Turn the machine off and unplug the power cord.
Disconnect connector J7 from the power supply unit.
When you turn the door switch (SW2) ON, is there
continuity between connectors J7-1 (+24VB) and
J7-2 (+24VA)? Replace the door switch.
Watch the drum motor during POST. Does it rotate?
Replace and check as follows:
1. Drum motor.
2. Mechanical controller PCB.
Check the connection on the transfer drum top
sensor connector J43. Replace and check as
follows:
1. Transfer drum top sensor.
2. DC controller PCB, see
Information" on page
Action
Replace the mechanical controller PCB.
"DC Controller Board
2-2.