5045-001
Note: Steps 12 through 14 may be skipped if an offset screwdriver
is used to remove the screws behind the oil bottle case.
12. Use the hypodermic syringe tool (11A2440) to withdraw the oil
from the bottle case. Also remove the square cap from the oil
tray and withdraw the oil from the oil tray. Store the oil withdrawn
in the oil storage bottle tool (11A2441).
13. Pinch or stop up the tube between the oil bottle case and the oil
tray to prevent oil from leaking out.
14. Place the fuser assembly on a shop towel or paper to catch any
spilled oil.
15. Remove the four screws from the oil bottle case and remove the
case.
16. Remove the screws from lamp wires.
17. Remove the two screws from the copper terminal jumper and
remove the jumper from the thermistor block.
18. Open the fuser delivery assembly.
19. Remove the two screws from the thermistor block. Slide the
block up and out of the fuser.