Static Vlan Configuration Screen Field Descriptions - Enterasys 6E2xx Local Management User’s Manual

Matrix e7 series and smartswitch 6000 series modules
Table of Contents

Advertisement

Field Descriptions
Refer to
Table 8-2
for a functional description of each screen field. Refer to
Section 8.3.5
for the application of these fields.
Table 8-2 Static VLAN Configuration Screen Field Descriptions
Use this field...
VLAN ID
– top of screen
(Read-Only)
FDB ID
(Read-Only)
VLAN Name
– top of screen
(Read-Only)
VLAN ID
– bottom of screen
(Modifiable)
VLAN Name
– bottom of screen
(Modifiable)
ADD
(Command)
DEL MARKED
(Command)
To...
See the assigned VLAN IDs that are configured in the switch module.
Initially, only the Default VLAN (VLAN ID: 1) is listed. Up to ten
VLANs can be displayed in the screen.
If there are more than ten VLANs, the NEXT command appears at the
bottom of the screen to allow stepping to the next screen.
See the Filter Database ID (FDB ID) numbers of the associated
VLAN IDs. This value is allocated automatically by the device when
the VLAN is created: either dynamically by GVRP, or when a Static
VLAN is created using this screen.
See the VLAN Name of the associated VLAN ID. If a name has not
been assigned to a VLAN, no name is displayed in the VLAN Name
field.
Enter a VLAN ID (VID) number (2 to 4094) for the new VLAN. Up to
1024 VLANs are supported by the switch module.
Assign or change names of VLANs. The VLAN Name (with up to 32
characters) is an optional attribute of a VLAN, and is not required for
VLAN operation.
Add the new VLAN to the switch module. If this is successful, the
screen refreshes and the new VLAN is added to the list in the screen.
Delete the VLANs shown in the screen marked with an asterisk to the
left of the VLAN ID number. The Default VLAN cannot be marked
and deleted.
Static VLAN Configuration Screen
802.1Q VLAN Configuration Menu Screens
Section 8.3.1
through
8-7