4.3.26 Back-up Roller, Transfer Roller
1.
After removing the Lower Base, remove the
spring.
2.
Lift the left side of the Back-up Roller and
pull it out leftwards.
Caution:
- Do not lose the ground washer.
- Do not bend the ground plate.
- Do not damage the backup roller.
3.
Release the gear by unlocking the latch on
the Lower Base.
4.
Lift the right side of the Transfer Roller and
shift rightwards, then pull it out from the
Lower Base.
Copyright 1998, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner
Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Service Guide OKIFAX 5700/5900
Chapter 4 Disassembly
Page: 192