4.3.19 Scanner Motor
1.
Remove the scanner latch.
2.
Remove the motor cable and
unscrew two screws (1) to remove
the motor along with the bracket.
Caution: Do not remove the four
screws* securing the motor.
3.
Remove the bracket and ground
plate by unscrewing two screws.
4.
Remove the damper by unscrewing
two screws.
Caution: As a maintenance part, the
damper is available separately from
the motor. Keep the damper without
throwing it away.
Precautions for Installation
Service Guide OKIFAX 5700/5900
Chapter 4 Disassembly
Page: 185