88
CHAPTER 8
Maintenance

Cleaning the foil squeegee

Wipe the foil squeegee with ThermApprove cleaning cards or a clean, lint-free cloth moistened
with 99% isopropyl alcohol and let air dry.

Replacing maintenance parts

You will need to replace material or foil squeegees on a yearly basis and fuses as required. One
set of replacement maintenance items are included in the accessories box. Use the chart below to
keep record of the replacement dates.
Maintenance part
Foil squeegee
Bail arm material squeegees
Fuses

Replacing the foil squeegee

Replace the foil squeegee immediately if it is bent or damaged. Even if the foil squeegee is
undamaged you should replace it once a year. Remove the four Phillips head screws that attach
the foil squeegee making note of its position. Discard the squeegee. Attach the new foil
squeegee using the same screws. One replacement foil squeegee is included in the original
accessory box. Additional squeegees can be obtained from GSP Customer Service.
Frequency
yearly (or sooner if needed)
yearly (or sooner if needed)
as needed
Foil squeegee
Print head
Replacement dates