64
CHAPTER 7
Troubleshooting
Message
Close Cover !
Over Temperature !
Incorrect Foil !
Using Short Foil !
Not Gerber Foil !
Foil Mismatch !
Use GerberGauge !
Unknown Material !
Unknown Foil !
Warmup Error !
Reset to factory
defaults ! Press any
key...
System Update Mode
System update in pro-
gress, please stand by
Network Error !
Description
The cover is open. Close the cover and press F1, RETRY to resume
the job.
The thermal print head (TPH) thermistor reading exceeds the set
thermal shutdown value. Wait for the TPH to cool down. Press F1,
RETRY to clear the error and try again.
The inserted foil doesn't match the foil in the job. This message is
displayed only for a legacy job. Pressing F1, OK allows the incorrect
foil to be used. Pressing F3, CANCEL returns to the FOIL MENU.
Either insert a cassette with the correct foil or continue with the
incorrect foil. Since this is a legacy job, no substitution is allowed.
The length of the foil in the cassette is shorter than what is required
for the job. Insert a cassette with an adequate amount of foil, or press
F1, OK to proceed with inadequate foil amount.
The foil is not manufactured by Gerber and the foil characteristics
can not be determined. Insert a Gerber foil.
The foil inserted does not have settings for the material in the job
(i.e., it is not a supported material/foil combination). Press F1,
RETRY to return to the FOIL MENU.
The length of the foil is unknown. Usually due to a power failure
that prevented the cassette RFID from being updated properly.
Replace with a working cassette, or press F1, OK to use the foil.
Material is unknown. Job can not be resumed. Check the material
specified in the job. Press F3, CANCEL to abort the job.
Foil is unknown. Job can not be resumed. Check the foil specified in
the job. Press F3, CANCEL to abort the job.
The TPH did not reach the set warm up temperature during the
predetermined time period. Press F1, RETRY to clear the error and
try again.
The Left and Right Slew keys were pressed during system power-up
causing the system settings to be restored to factory default values.
Press any key to continue.
The firmware is being updated. This mode can be canceled.
The firmware is being updated. This process can not be canceled.
There is a problem with the GERBER EDGE FX network hardware.
Check network cable connections and/or consult your network
administrator.