v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3655, Type 7985 and 7943," on page 93 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System event/error log message
CPU n non-recoverable over temperature fault
VRD 1 critical over voltage fault
VRD 1 critical under voltage fault
VRD 2 critical over voltage fault
VRD 2 = VRM
VRD 2 critical under voltage fault
VRD 2 = VRM
Processor VTT power fault

IPMI BMC system-error log messages

The following table describes the possible IPMI BMC system-event log messages
and suggested actions to correct the detected problems.
Action
1. Make sure that the fans are operating, that there are no
obstructions to the airflow, that the air baffles are in place and
correctly installed, and that the server cover is installed and
completely closed.
2. Make sure that the heat sink for microprocessor n is installed
correctly.
3. (Trained service technician only) Replace microprocessor n.
4. (Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor 1.
2. (Trained service technician only) Replace microprocessor 1.
3. (Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor 1.
2. (Trained service technician only) Replace microprocessor 1.
3. (Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor 2.
2. (Trained service technician only) Replace microprocessor 2.
3. (Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor 2.
2. (Trained service technician only) Replace microprocessor 2.
3. (Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor 1.
2. (Trained service technician only) Replace microprocessor 1.
3. (Trained service technician only) Replace the system board.