Unit Load Calculation Work Sheet
1. Number of modules in carrier (excluding power supply module and
processor module)
If fewer than 5, auxiliary power is not required.
If 5 or 6, continue to step 2.
2. Key or Behind Switch mode only
Indicate configuration of lines; then go to step 5
3. Hybrid/PBX mode only:
Do all modules in the carrier have MLX and/or analog
multiline station jacks?
If no, auxiliary power is not required.
If yes, continue to step 4.
4. Hybrid/PBX mode only:
Calculate the total number of MLX and analog multiline telephones:
Number of MLX-20L telephones connected to modules in the carrier
Number of MLX28D telephones connected to modules in the carrier
Number of 34-button analog multiline telephones connected to
modules in the carrier
Total of MLX-20L, MLX-28D, and 34-button analog multiline telephones
If total is less than 45, auxiliary power is not required.
If total is 45 or more, continue to step 5.
H-2 Unit Load Calculation Work Sheet
Square
Modified
Yes
No