Hardware Information; Firmware Information; Heartbeat Led Activity - HP StorageWorks SN6000 Command Line Interface Manual

Fibre channel switch
Hide thumbs Also See for StorageWorks SN6000:
Table of Contents

Advertisement

Hardware information

To display the status of the switch hardware, including fans, power supplies, internal temperature, and
Heartbeat LED status, enter the show chassis command.
The following is an example of the show chassis command:
SN6000 FC Switch #> show chassis
Chassis Information
-------------------
BoardTemp (1) - Degrees Celsius
BoardTemp (2) - Degrees Celsius
BoardTemp (3) - Degrees Celsius
PowerSupplyStatus (1)
HeartBeatCode
HeartBeatStatus
The HeartBeatCode and HeartBeatStatus entries indicate the power-on self test (POST) results
revealed by the Heartbeat LED blink patterns. The result is normal operation or a blink pattern indicating a
critical error as described in
StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide.
Table 3

Heartbeat LED activity

HeartBeatCode–HeartBeatStatus
1-Normal
2-AppDied
3-PostFailed
4-CorruptFilesystem
5-Overheating

Firmware information

To display a summary of switch identity information, including the firmware version, enter the
show version command. The following is an example of the show version command:
SN6000 FC Switch #> show version
*****************************************************
*
*
*
*****************************************************
SystemDescription
HostName
EthIPv4NetworkAddress
EthIPv6NetworkAddress
MACAddress
WorldWideName
ChassisSerialNumber
SymbolicName
ActiveSWVersion
ActiveTimestamp
POSTStatus
LicensedPorts
SwitchMode
Table
3. For information about Heartbeat LED blink patterns, see the HP
Description
One blink per second–Normal operation
Two blink cluster–Internal firmware failure
Three blink cluster–Fatal POST error
Four blink cluster–Configuration file system error
Five blink cluster– Over temperature
Command Line Interface SHell
HP StorageWorks SN6000 DualPower Supply Fibre
Channel Switch
<undefined>
10.20.11.192
::
00:c0:dd:00:71:ee
10:00:00:c0:dd:00:71:ed
FAM033100024
SN6000 FC Switch
V8.0.x.x.xx.xx
day month date time year
Passed
24
Full Fabric
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide
26
31
31
Good
1
Normal
(CLISH)
*
*
*
41

Hide quick links:

Advertisement

Table of Contents
loading