To enable port binding for the selected port and to specify the WWNs of the authorized ports/devices,
enter the set config security portbinding command. The following example enables port
binding on port 1 and specifies two device world wide names:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> config edit
SN6000 FC Switch (admin-config) #> set config security port 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
PortBindingEnabled (True / False)[False] true
WWN
WWN
WWN
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.

Resetting a port

To reinitialize one or more ports and to discard any temporary changes that have been made to the
administrative state or link speed, enter the reset port command. The following example reinitializes
port 1:
SN6000 FC Switch #> reset port 1

Configuring port threshold alarms

The switch can monitor a set of port errors and generate alarms based on user-defined sample windows
and thresholds. These port errors include the following:
Cyclic redundancy check (CRC) errors
Decode errors
ISL connection count
Device login errors
Device logout errors
Loss-of-signal errors
You make changes to the port threshold alarms by modifying the switch configuration as described in
"Modifying a switch
parameters.
The switch will down a port if an alarm condition is not cleared within three consecutive sampling windows
(by default, 30 seconds). Reset the port to bring it back online. An alarm is cleared when the threshold
monitoring detects that the error rate has fallen below the falling trigger.
(N=None / WWN)[None ] 10:00:00:c0:dd:00:b9:f9
(N=None / WWN)[None ] 10:00:00:c0:dd:00:b9:f8
(N=None / WWN)[None ] n
configuration" (page 45). See
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide
Table 37
for a description of the port alarm threshold
65