HP StorageWorks SN6000 Command Line Interface Manual page 295

Fibre channel switch
Hide thumbs Also See for StorageWorks SN6000:
Table of Contents

Advertisement

Table 72
Switch test parameters (continued)
Parameter
StopOnError
LoopForever
Examples The following example performs an offline internal test on a switch:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #>set switch state diagnostics
SN6000 FC Switch (admin) #> test switch offline internal
A list of attributes with formatting and current values will follow. Enter a
new value or simply press the ENTER key to accept the default value. If you
wish to terminate this process before reaching the end of the list press 'q'
or 'Q' and the ENTER key to do so.
LoopCount
FrameSize
DataPattern
StopOnError
LoopForever
Do you want to start the test? (y/n) [n] y
See also
test
cancel, page 289
test
status, page 292
test
switch, page 294
Description
Stops the test when an error occurs (True). Otherwise, the test continues to
completion.
Restarts the test after completion and continues until you cancel it (True).
Otherwise, the test ends normally after completion.
(decimal value, 1-4294967295)
(decimal value, 40-2148)
(32-bit hex value or 'Default') [Default]
(True / False)
(True / False)
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 295
[100
]
[256
]
[True
]
[False
]